1012 and 1024 Power Supplies (DISCONTINUED - See 10-1 & 10-1FPD)

RCI's filtered and regulated 10 Series DC Power Supplies are designed with safety and reliability in mind, especially when it comes to electromagnetic locks. FPD models incorporate many life safety features required by the National Building Code such as fire panel disconnect, instant unlock upon power failure and remote override reset capabilities for authorized personnel.

Standard features include universal knock-outs and built-in battery charging circuits.

Applications

Airport Facilties Fire Rated Stairwell factory inside door Exhibit
• To power Access Control Systems
• To power Electric Locking Systems

2 year

STANDARD FEATURES

  • Instant Unlock upon AC failure* (FPD Only)
  • Filtered, regulated DC Output
  • Short Circuit Protection
  • Adjustable Output Voltage
  • Fuse Protection
  • Fire Panel Disconnect* (FPD Only)
  • Remote override reset capability* (FPD Only)
  • Exceeds safety codes
  • Optional battery backup and time delay
  • Manual Override output* (FPD Only)

* Required by National Building Code when used with Electromagnetic locks

Features Benefits FPD-1 FPD-2 FPD-3
Filtered DC Output If the DC voltage is not filtered, the result will be reduced holding force or intermittent buzzing or humming. Most electronic equipment requires a filtered (clean) input to ensure reliable operation.
Regulated DC Output The DC output voltage will remain constant with changes in load (resistance).
Adjustable Output Voltage The DC output is adjustable to compensate for line loss that can be encountered in long wire runs.
Short Circuit
Protection
Short circuit protection is provided by both a Fuse (located on the printed circuit of the power supply), and a short circuit protection relay. In the event of a short circuit between the positive and negative output of the power supply, the short circuit relay will de-activate, opening its contacts, removing power to the electric locking device. The fuse provides back-up protection to the relay.
Fuse Protection The power supply has a backup fast blow fuse located on the Printed Circuit Board.
Fire Panel
Disconnect*
Provision is made for fire panel disconnect. - - -
Instant Unlock Upon Power Failure* Magnetic locks will release instantly upon failure of AC power source. -
Manual Override Output* Provision is made for a manual override output connections on the terminal block located inside the power supply housing. This switch disconnects the DC voltage from the output when the switch is opened. -
Reset Switch* The FPD-2 has a momentary action reset switch installed on the cover. This switch can be paralleled with a remote reset switch. The purpose of the reset switch is to reset the short circuit and DC power output relay located in the power supply housing. The FPD-1 has reset input.
Built-In Battery Charger The built in battery charger has a low battery disconnect to prevent deep discharge of backup batteries. Automatic switch-over to battery in the event of an AC power failure. With FPD-1 and FPD-2, the fire alarm panel will disconnect the batteries to allow instant release in the event of a fire.
Power Lamp
Indicator
A green DC power indicator lamp is mounted on the FPD-2 cover, to show the presence of DC voltage on the output. The FPD-1 and NR-1 have a green AC input power indicator lamp mounted on the cover.

OPTIONS
TD1........... Time Delay option - Delayed Unlock - Manual Relock,  NFPA-101 (15 Sec. Delay)

TD2........... Time Delay option - Delayed Unlock - Auto-Relock
This two stage time delay option provides the same function as the TD1, only, instead of manual relock, the door locks again automatically after the specified (adjustable) period of time.


TD3........... Time Delay option - Instant Unlock - Delayed Auto-Relock
Upon actuation of a momentary switch (e.g. push button, key switch, keypad) the door unlocks immediately and automatically relocks after a preset (adjustable) period of time has elapsed.


TD4........... Time Delay option - 3 Second Nuisance Delay - Manual Relock

TD365
........... 365 Day Timer
BB12-4........... 4.5 Ahr Battery (1) 
BB12-7........... 7 Ahr Battery (1)   
BB24-4........... 4.5 Ahr Battery (2)  
BB24-7........... 7 Ahr Battery (2)   
9310RB........... Relay Board

WARRANTY
2 Year Limited Warranty

Dimensions:
10-1/4"H x 10-1/4"W x 4"D

Certifications:

Security ULcULusESA
Model Description Dimensions Voltage
1012NR-1A No Relay Power Supply 10-1/2"H x 10-1/2"W x 4"D 12VDC-1 amp
1024NR-1A No Relay Power Supply 10-1/2"H x 10-1/2"W x 4"D 24VDC-1 amp
1012FPD-1A Fire Panel Disconnect 10-1/2"H x 10-1/2"W x 4"D 12VDC-1 amp
1024FPD-1A Fire Panel Disconnect 10-1/2"H x 10-1/2"W x 4"D 24VDC-1 amp
1012FPD-2A Fire Panel Disconnect 10-1/2"H x 10-1/2"W x 4"D 12VDC-2 amps
1024FPD-2A Fire Panel Disconnect 10-1/2"H x 10-1/2"W x 4"D 24VDC-2 amps

 

OPTIONS
Model Description Dimensions
TD1 Time Delay option - Delayed Unlock - Manual Relock,  NFPA-101 (15 Sec. Delay) -
TD2 Time Delay option - Delayed Unlock - Auto-Relock
-
TD3 Time Delay option - Instant Unlock - Delayed Auto-Relock
-
TD4 Time Delay option - 3 Second Nuisance Delay - Manual Relock -
TD365 365 Day Timer
-
BB12-4 4.5 Ahr Battery (1)  - 12VDC 
3-1/2"L x 2-3/4"W x 4"H 
BB12-7
7 Ahr Battery (1) - 12VDC
5-15/16"L x 2-9/16"W x 3-1/2"H
BB24-4
4.5 Ahr Battery (2) - 24VDC
3-1/2"L x 2-3/4"W x 4"H
BB24-7 
7 Ahr Battery (2) - 24VDC 5-15/16"L x 2-9/16"W x 3-1/2"H
9310RB
Relay Board - 12/24 VDC-10 amp -