1300 High Security Electrified Rim Exit Devices
RCI's 1200 and 1300 Series exit devices resolve the conflict between life safety
and security. Both 1200 Mechanical and 1300 Electric Series exit devices feature a patented latch that rotates to engage and grip the specially designed strike. This unique interlocking grip action secures the door to the jamb without conventional roller strikes or retracting latches.

Panex Latch

Pannex_Latch_Applicaion

In addition an interlocking mechanism located in the chassis offers a double interlocking system which makes these exit devices virtually impossible to tamper with, pry or force open. The attractive lever trim can be used on the exterior side of the door for access.

Applications

Airport Arena Facilties health care factory back door office corridor perimeter Stairwell Retail library healthclub Exhibit

• Use 120, 1200 or 1300 Series with any 3 or 4-foot-wide doors
• Use with all types of doors, including narrow-stile aluminum
• Any exterior door exposed to possible tampering

securityfire labeled3 year

STANDARD FEATURES

  • Model 1300 includes a 12/24VDC dual voltage continuous-duty solenoid which provides a remote unlock feature for controlled entry.
  • Field Selectable 12/24 VDC (24VDC@0.4A / 12VDC@0.8A)

Plus all the same features as the 1200 Mechanical Rim Exit Devices:

  • Weather resistant for outddor use
  • Current of less than 800mA @ 12VDC and 400mA @ 24VDC is required to unlock the device or to dog it unlocked. (fire rated devices must be powered through contact of a fire-alram system relay)
  • All models re-latch
  • Pre-assembled for easy installation
  • Camlock and cylinder dogging available (for non-fire labeled doors)
  • Choice of 3 alarm modules (standard)
  • Standard lengths for 36" (3 feet) and 48" (4 feet) doors
  • Can be field cut for undersized doors
  • Non-handed for installing on all types of doors, including narrow stile aluminum
  • High security, exceeding a 1" deadbolt
  • Made in the USA

OPTIONS
1200C/1300C...... Cylinder dogging
1200D/1300D...... Cam lock dogging
1200F/1300F....... Fire labeled exit device, no dogging
10 ..................... Alarm module (9V battery supplied)
20...................... 10-26 VDC alarm module (remote power with battery backup; 9V battery supplied)
30...................... 10-26 VDC alarm module (remote power only)
SS1.................... SPDT Signal Switches
SS2.................... Two SPDT Signal Switches
LMS ................... Lock Monitor Switch
DDS.................... Double Door Strike

Finishes
28 ..................... Aluminum (BHMA 628)
40...................... Dark Duranodic (BHMA 710)

Trim Options
08-L.................. Lever Trim
08N-L................ Narrow stile lever trim
08E-L ............... Electrified lever trim
08NE-L.............. Narrow stile electrified lever trim
03-P.................. Pull Trim

WARRANTY
3 Year Limited Warranty


Signal Switches* Activated by depressing push bar. Switches can be specified for all types of access controls. SS1 - SPDT rated 3A@30VDC (Inductive), 4A @ 30VDC (Resistive) SS2 - 2SPDT rated 3A @ 30VDC (Inductive), 4A @ 30VDC (Resistive)
Lock Monitor Switch For remote alarm monitoring of latch position. Normally opened, normally closed contacts.
Push Bar Inserts Black vinyl insert supplied. Allows inserts to be added by removing push bar end cap and sliding insert into the
groove of the push bar.
Alarm Module 10 - Operated by a 9V alkaline battery (supplied)
20 - Remotely powered field-selectable 10 to 26VDC power with a 9V battery backup (supplied)
30 - Remotely powered field-selectable 10 to 26VDC power.
Alarm Module Current Draw Alarm Module 10 - 0.5 microA in Standby position; 16mA when sounding
Alarm Module 20 - 0.5 microA in Standby position; 16mA when sounding
Alarm Module 30 - 0.5 microA in Standby position; 16mA when sounding
Alarm Horn Power 110db piezo horn; field-selectable continuous horn or 3 to 5-minute sound and reset; field-selectable intermittent
beep or steady horn. Activated by depressing push bar when in the "Alarm On" position.
Low Battery Alert Audible chirp indicates low battery (1 chirp/minute). Activated by 7.6 volts
Current Draw Electrified Trim 155mA@24VDC

1200/1300 Series Certification:

cULus ADA

Accepted by NYC MEA 337-92M, Listed by CA State Fire Marshal; ADA compliant
Models with A.C or D suffix; cULus Listed Panic Hardware ANSI/BMHA A156.3-2001, Grade 1,
Models with F suffix; cULus Fire Exit Hardware rated 3 hours,ANSI/BMHA A156.3,
Grade 1 Conforms to ANSI/UL10C and UBC 7-2 (1997)

Model Description Door Length Finish
1300A x 28
Electrified Rim Exit Device, No Dogging 24 to 36"
28
1300A x 40
Electrified Rim Exit Device, No Dogging 24 to 36"
40
L1300A x 28
Electrified Rim Exit Device, No Dogging 
37 to 48" 28
L1300A x 40
Electrified Rim Exit Device, No Dogging 
37 to 48" 40
1300D x 28
Electrified Rim Exit Device, Cam Lock Dogging
24 to 36"
28
1300D x 40
Electrified Rim Exit Device, Cam Lock Dogging
24 to 36"
40
L1300D x 28
Electrified Rim Exit Device, Cam Lock Dogging 37 to 48"   
28
L1300D x 40
Electrified Rim Exit Device, Cam Lock Dogging 37 to 48"   
40
1300F x 28
Electrified Rim Exit Device for Fire Doors
(Fire Listed B Label)  
24 to 36" 
28
1300F x 40
Electrified Rim Exit Device for Fire Doors
(Fire Listed B Label)  
24 to 36" 
40
L1300F x 28
Electrified Rim Exit Device for Fire Doors
(Fire Listed B Label)
37 to 48" 28
L1300F x 40
Electrified Rim Exit Device for Fire Doors
(Fire Listed B Label)
37 to 48" 40
1310A  x 28
Electrified Rim Exit Device, No Dogging, Alarm Module
(9V Battery)
32 to 36" 28
1310A x 40
Electrified Rim Exit Device, No Dogging, Alarm Module
(9V Battery)
32 to 36" 40
L1310A x 28
Electrified Rim Exit Device, No Dogging, Alarm Module
(9V Battery) 
37 to 48" 
28
L1310A x 40
Electrified Rim Exit Device, No Dogging, Alarm Module
(9V Battery) 
37 to 48" 
40
1310D x 28
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(9V Battery)
32 to 36"
28
1310D x 40
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(9V Battery)
32 to 36"
40
L1310D x 28
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(9V Battery)
37 to 48" 
28
L1310D x 40
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(9V Battery)
37 to 48" 
40
1310F x 28
Electrified Rim Exit Device for Fire Doors, Alarm Module
(9V Battery, Fire Listed B Label)
32 to 36"
28
1310F x 40
Electrified Rim Exit Device for Fire Doors, Alarm Module
(9V Battery, Fire Listed B Label)
32 to 36"
40
L1310F x 28
Electrified Rim Exit Device for Fire Doors, Alarm Module
(9V Battery, Fire Listed B Label)
37 to 48" 28
L1310F x 40
Electrified Rim Exit Device for Fire Doors, Alarm Module
(9V Battery, Fire Listed B Label)
37 to 48" 40
1320A  x 28
Electrified Rim Exit Device, Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36" 
28
1320A  x 40
Electrified Rim Exit Device, Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36" 
40
L1320A  x 28
Electrified Rim Exit Device, Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"  
28
L1320A  x 40
Electrified Rim Exit Device, Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"  
40
1320D x 28
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36"
28
1320D x 40
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36"
40
L1320D x 28
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"  
28
L1320D x 40
Electrified Rim Exit Device, Cam Lock Dogging, Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"  
40
1320F x 28
Electrified Rim Exit Device, Fire Doors, Alarm Module
(Field-selectable 12-24VDC Remote, 9V Battery Backup) Fire Listed B Label
32 to 36"
28
1320F x 40
Electrified Rim Exit Device, Fire Doors, Alarm Module
(Field-selectable 12-24VDC Remote, 9V Battery Backup) Fire Listed B Label
32 to 36"
40
L1320F x 28
Electrified Rim Exit Device, Fire Doors, Alarm Module
(Field-selectable 12-24VDC Remote, 9V Battery Backup) Fire Listed B Label
37 to 48"  
28
L1320F x 40
Electrified Rim Exit Device, Fire Doors, Alarm Module
(Field-selectable 12-24VDC Remote, 9V Battery Backup) Fire Listed B Label
37 to 48"  
40
1330A x 28
Electrified Rim Exit Device, with Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36"
28
1330A x 40
Electrified Rim Exit Device, with Alarm Module
(Field-selectable 12-24VDC Remote)
32 to 36"
40
L1330A x 28
Electrified Rim Exit Device, with Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"
28
L1330A x 40
Electrified Rim Exit Device, with Alarm Module
(Field-selectable 12-24VDC Remote)
37 to 48"
40
1330D x 28
Electrified Rim Exit Device, Cam Lock Dogging
(Field-selectable 12-24VDC Remote)
32 to 36" 28
1330D x 40
Electrified Rim Exit Device, Cam Lock Dogging
(Field-selectable 12-24VDC Remote)
32 to 36" 40
L1330D x 28
Electrified Rim Exit Device, Cam Lock Dogging
(Field-selectable 12-24VDC Remote)
37 to 48" 28
L1330D x 40
Electrified Rim Exit Device, Cam Lock Dogging
(Field-selectable 12-24VDC Remote)
37 to 48" 40
1330F x 28
Electrified Rim Exit Device for Fire Doors, Alarm Module 
(Field-selectable 12-24VDC Remote) Fire Listed B Label
32 to 36"
28
1330F x 40
Electrified Rim Exit Device for Fire Doors, Alarm Module 
(Field-selectable 12-24VDC Remote) Fire Listed B Label
32 to 36"
40
L1330F x 28
Electrified Rim Exit Device for Fire Doors, Alarm Module 
(Field-selectable 12-24VDC Remote) Fire Listed B Label
37 to 48"
28
L1330F x 40
Electrified Rim Exit Device for Fire Doors, Alarm Module 
(Field-selectable 12-24VDC Remote) Fire Listed B Label
37 to 48"
40

Rim Exit Device, Cylinder Dogging

Finish 28 - Brushed Anodized Aluminum
Finish 40 - Brushed Anodized Dark Bronze

Options

Model Description Finish
DDS Double Door Strike Black Oxide
SS1 Signal Switch (SPDT) -
SS2 Signal Switch (2 SPDT) -
SS1W Single Switch (SPDT) Weather-proof with mounting hardware -
SS1A 1210/1220/1230/1310/1320/1330 alarm signal (SPDT) -
SS2A 1210/1220/1230/1310/1320/1330 alarm signal (2 SPDT) -
LMS Lock Monitor Switch. Rated 5A, 250V DC.
Specify with alarmed exit devices for remote alarm monitoring
-

For Cylinder Dogging, Alarm Modules or 08 Lever Trim use 96CYL or use 1-1/8" - 1-1/4" Grade 1 Standard Yale Cam (.718") Mortise Cylinder.