Delayed Egress Electromagnetic Lock

The Delayed Egress Electromagnetic Lock is an All-in-One delayed egress lock with a built-in sensor that detects pressure applied to outward swinging doors. Built-in sounder makes this ideal for applications requiring Loss Prevention, Life Safety and Traffic Control. The DE8310 is unique in that there is no need to replace existing door hardware making this an easy and affordable delayed egress solution.

Applications

Old age home shoplifting Airport Exhibit
  • Health Care Facilties
  • Retail & Wholesale Centers
  • Airports
  • Public Transit Buildings
  • Museums & Galleries

DE8310 PRODUCT VIDEOS

you tubeWatch the latest DE8310 Product Review Video

DE8310 Demonstration Video

Full Length DE8310 Demonstration Video
Condensed DE8310 Demonstration Video

securitylow energyEasy5 year

STANDARD FEATURES

  • All-in-One delayed egress lock
  • Built in "sensor" detects when pressure is applied to outward swinging doors - No need to replace existing door hardware
  • Field selectable 15 or 30 second release delay with field selectable 0 to 3 second nuisance delay
  • Provision for IBC, SBC, NFPA101, UBC, BOCA or NBC of Canada compliance
  • Unique highly visible "Red/Green" light panel indicates status of door (local)
  • Available with built-in sounder
  • Includes 960 Keyswitch for reset and override, 15 second Building Code Sign; base unit includes external sounder
  • Built-in Security Condition Sensor (SCS) feature indicates that the door is closed and bonded
  • Dry contact SPDT and DPDT relays provided for local and/or remote monitoring
  • Auto sensing voltage from 12 to 24 VDC
  • Up to 1200lbs (540kg) holding force


PLUS! Standard MultiMag® features included

  • Adjustable keyhole mounting
  • Convenient plug-in wiring terminals
  • Easy access wiring cavity
  • Encapsulated 4-bolt 'Drop-Stop" mounting
  • Self-drilling tek™ fasteners

FEATURE AND FUNCTION DESCRIPTIONS

Nuisance Delay This feature is designed to accommodate accidental triggering. A pull to the door with a minimum of 15 lbs of force changes the light panel from green to red and triggers the local alarm relay. If the pressure is withdrawn within 1, 2, or 3 seconds (as set by the dip switches 2 and 3 in Installation Instructions), the system will return to normal. If the nuissance period is set to 0 (0 seconds is no nuisance period) removing pressure will not stop alarm.
15 Second Alarm Period If pressure on the door is maintained for more than the selected nuisance period (1, 2, or 3), the remote alarm relay will activate, the local alarm relay remains on and the light panel continues to flash red.
After 15 seconds, the local and remote alarm relay will remain in its de-activated state until the lock has been reset, but the light panel will continue to blink indicating attempted break-in has occurred to the EW magnet.
Light Panel This full length feature is a highly visible red and green status indicator.

NOTE: All installations must be approved by the Local Authority Having Jurisdiction (AHJ)

WARRANTY

  • 5 Year Warranty on electromagnetic lock.
  • 1 Year Warranty on built-in sounder component


OPTIONS

  • KA - Keyed alike on the 960 Key Switch (no charge)

Housing Dimensions:

Base Unit

2-1/8" (54mm) Deep x 2-7/8" (73mm) High Profile with 10-13/16 (275mm) Length
with Sound Option 2-1/8" (54mm) Deep x 2-7/8" (73mm) High Profile with 11-3/4" (299mm) Length

This includes the 1/4" (6mm) mounting bracket

Armature Plate Requirements:
5/8"D x 2-3/8"H x 7-7/16"L (16mm x 60mm x 189mm)

Auto Sensing Voltage:
12VDC to 24VDC

Power Consumption:
With Sound:  12VDC - Max 0.66A / 24VDC - Max 0.33A
Base Unit*:  12VDC - Max 0.61A / 24VDC - Max 0.32A
* Ratings shown include the external sounder required by NFPA101

Local Alarm Output:
SPDT  1.0A 120VAC, 2A 30VDC

Remote Alarm Output:
DPDT: 1.0A 120VAC, 2A 30VDC

NOTE: RCI recommends our filtered, regulated DC voltage 10 Series power supplies.

Certification:

cULusUL 10C Auxiliary Locks Listed for fire doors rated up to 1-1/2-hour
UL 294 Special Locking Arrangements Component

cURuscURus Component for use in FWAX Special Locking Arrangements

Holding Force:
Up to 1200 lbs (540kg) pounds

Operating Temperature:
Circuit board operating temperature: 14° to 140°F (-10° to 60°C)
Not for use in outdoor environments.

Model

Description

Dimensions

Finish

Spacers
SPDE-01 1/4" Spacer for Base Unit 1/4"Dx 2-7/8"H x 10-13/16"L
SPDE-02 3/8" Spacer for Base Unit 3/8"Dx 2-7/8"H x 10-13/16"L
SPDE-03 1/2" Spacer for Base Unit 1/2"Dx 2-7/8"H x 10-13/16"L
SPDE-04 5/8" Spacer for Base Unit 5/8"Dx 2-7/8"H x 10-13/16"L
SPDE-SV-01 1/4" Spacer for Sounder 1/4"Dx 2-7/8"H x 11-3/4"L
SPDE-SV-02 3/8" Spacer for Sounder 3/8"Dx 2-7/8"H x 11-3/4"L
SPDE-SV-03 1/2" Spacer for Sounder 1/2"Dx 2-7/8"H x 11-3/4"L
SPDE-SV-04 5/8" Spacer for Sounder 5/8"Dx 2-7/8"H x 11-3/4"L


Model Description
DE8310VMF French voice module with French signage
DE8310VMS Spanish voice module with Spanish signage
BC1M-30 30 Second Building Code Sign
1012FPD-1A
(Canada ONLY)
cULus
1A Power Supply with Fire Panel Disconnect
1024FPD-1A
(Canada ONLY)
cULus
1A Power Supply with Fire Panel Disconnect
10-175UL
(USA ONLY)
UL
Power Supply with Fire Release Relay

 

Armature plate holders, angle brackets and filler bars for base DE8310 click here.

Model Description Dimensions Voltage Finish

DE8310

UL UR

Delayed Egress with external sounder

Includes: 960 Keyswitch for reset and override (keyed different),
BC1M -15 second building code sign, External sounder

2-1/8"D x 2-7/8"H x 10-13/16"L 12 to 24VDC 28

DE8310S

UL UR

Delayed Egress with internal sounder

Includes: 960 Keyswitch for reset and override (keyed different),
BC1M-15 second building code sign, Built-in sounder
2-1/8"D x 2-7/8"H x 11-3/4"L 12 to 24VDC 28

Finish 28 - Brushed Anodized Aluminum


DE8310 Options

NOTE